The Time Control Process is used to keep electric time synchronized with conventional clock time. Electric time is calculated by accumulating the frequency deviations of the power system. If the average system frequency deviates from 50 Hz over time, electric time will gradually run ahead of or behind conventional time.

To reduce an accumulated time deviation, the TSOs must temporarily steer the frequency in the opposite direction. For example, if the frequency has been below 50 Hz for an extended period, it must subsequently be maintained somewhat above 50 Hz in order to reduce the time deviation. This results in balancing actions that are not required to manage the actual balance between generation and consumption. Consequently, these actions may lead to unnecessary use of balancing resources and increased costs.

Historically, time control had greater practical importance. For example, synchronous-motor-based electric clocks and certain industrial processes used grid frequency as a time reference.

The modernization and digitalization of the power system have significantly reduced this need. Modern clocks and time-critical systems are now primarily synchronized to other time sources. At the same time, most electricity consumption and industrial processes are connected to the grid through frequency converters and other power electronic equipment and are therefore only marginally affected by long-term deviations in system frequency.

Trial period before final decision

The trial suspension will begin on 15 December 2026. The Nordic TSOs will monitor developments and assess whether the suspension has any undesirable consequences for the power system or for equipment that still relies on electric time.

The Nordic TSOs encourage all affected parties in the Nordic synchronous area to report any expected or experienced consequences caused by time deviation and the suspension of Time Control Process during the trial period, by reaching out to your national TSO, as indicated below.

The suspension will not affect normal balancing in the Nordic power system, except for balancing actions made for time error correction. The TSOs will continue to maintain the balance between generation and consumption, manage frequency deviations, and operate the Nordic power system at a nominal frequency of 50.00 Hz. The change applies only to the long-term correction used to keep electric time synchronized with conventional clock time.

If the trial period does not reveal any significant issues, the TSOs will consider permanently discontinuing the Time Control Process.

For further information, please contact your national TSO.

Contact:

For reporting consequences please use the following contact information and use "TCP test period" as the title.

Statnett: bsp@statnett.no